热门关键词:苏玛罐,原子吸收分光光度计,环境监测产品,液相色谱,色谱柱。
更新时间:2019-11-12
Dionex AminoPac PA10氨基酸分析色谱柱AminoPac PA10柱结合阴离子交换,梯度淋洗以及脉冲电化学检测,可以分离多种氨基酸。
免费咨询:010-61755520
用途和特点
AminoPac PA10柱结合阴离子交换,梯度淋洗以及脉冲电化学检测,可以分离多种氨基酸。分离氨基酸的同时,还可检测氨基糖及碳水化合物。此外,还可分离多种糖类,磷酸化氨基酸,以及含硫氨基酸的普通氧化产物,如磺基丙氨酸。其柱填料为疏水性高聚物薄壳型阴离子交换剂,可在pH0-14范围内使用。填料*的pH稳定性允许使用的淋洗液,有助于氨基酸在金电极的阳极氧化。
Dionex AminoPac PA10氨基酸分析色谱柱
订货信息:
分析柱 | |
AminoPac PA10 Analytical Column (2 x 250 mm) | 055406 |
AminoPac PA10 (22 x 250 mm) | SP5488 |
AminoPac PA10 (9 x 250 mm) | SP5490 |
AminoPac PA10 Analytical Column (4 x 250 mm) | SP5678 |
保护柱 | |
AminoPac PA10 Guard Column (2 x 50 mm) | 055407 |
AminoPac PA10 Guard Column (4 x 50 mm) | SP5680 |
配件 | |
AAA-Direct Installation Kit | 059539 |
Carbohydrate Removal Cartridge (CRC) for AAA-Direct | 068598 |
The AminoPac® PA10 column is packed with a hydrophobic, polymeric, pellicular, anion-exchange resin that is stable over the range of pH 0–14. The unique pH stability allows the use of eluents that are conducive to anodic oxidation of amino acids at gold electrodes. This column is recommended for use with the AAA-Direct™ Amino Acid Analyzer, allowing direct detection of primary and secondary amino acids by IPAD, with no need for pre- or postcolumn derivatization.
Derivatization not required
Carbohydrates and amino acids separated and detected simultaneously
Mid-femtomole to low-picomole detection limits
Compatible with all commonly used hydrolysis procedures
Can be configured for on-line analysis
AAA-Direct is a technique that eliminates the need for any form of derivatization, and is therefore compatible with on-line monitoring of cell cultures and fermentation broths.
The AminoPac PA10 column is optimized for separations of free amino acids by AAA-Direct. Vitamins, amino sugars, and carbohydrates can be detected simultaneously with amino acids. Additional capabilities include separation of a wide range of sugars, phosphorylated amino acids, and common oxidation products of sulfur-containing amino acids, such as cysteic acid, methionine sulfone, and methionine sulfoxide.
AminoPac PA10 Column for Amino Acid Analysis by AAA-Direct Specifications | |
---|---|
Recommended operating temperature | 30 °C |
Typical operating conditions | 0.25 mL/min gradient Recommended flow rate: 0.25 mL/min |
Mobile phase compatibility | pH 0–14; 100% compatible with common organic solvents. Dionex sodium acetate ionic form eluents only. |
Resin composition | 8.5-μm-diameter microporous (<10 ?) bead (55% cross-linked) agglomerated with an 80-nm microbead alkyl ammonium functionalized latex (1% cross-linked). |
Anion-exchange capacity | 60 μeq/column (2 × 250 mm analytical column) |
Column construction | PEEK with 10-32 threaded ferrule-style end fittings. All components are nonmetallic. |
Dimensions | AminoPac PA10 Analytical Column: 2 × 250 mm AminoPac PA10 Guard Column: 2 × 50 mm |
Maximum operating pressure | 4000 psi (27.9 MPa) |